5-3. Adjustment of White Balance
¥ Operate the Zero-calibration of the CA�100, then stick sensor to PDP module surface when you adjust. ¥ For manual adjustment, it is also possible by the following sequence. (1) Select WHITE PATTERN of HEAT RUN mode by pressing ADJ button on Remote Control for adjustment then operate HEAT RUN more than 15 minute. (2) Supply Full White signal(signal output level : 85IRE) in AV Pattern Generator. (3) Select image regulation status to �Clear Image�. (4) Stick sensor to the center of screen and press the ADJ Key on R/C to select W/B and then press the VOL + Key to enter the adjustment mode. After selecting R ADJ and B ADJ, press the VOL +/- Key and adjust it until color coordination becomes(B GAIN fixation) color coordination : X=0.280±0.003, Y=0.290±0.003 color temperature : 10,000cK ± 500cK (5) Exit adjustment mode using Enter button.